Toshiba e-STUDIO2008A Service Manual page 214

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2008A:
Table of Contents

Advertisement

Notes:
1. Do not touch the needle electrode [5]
directly with bare hands.
2. Make sure not to hold or bend the needle
electrode [5].
3. The form of the needle electrode [5]
differs depending on the model as shown
in the figure.
Do not mix them when installing.
4.7.8
Drum
(1)
Take off the main charger.
( P. 4-91 "4.7.4 Main charger")
(2)
Rotate the lever [2] while pushing the latch
[1]. Remove the lever [2] by pulling it toward
you.
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
DISASSEMBLY AND REPLACEMENT
20ppm/25ppm/30ppm
35ppm/45ppm/50ppm
Fig. 4-253
Fig. 4-254
© 2015 TOSHIBA TEC CORPORATION All rights reserved
4 - 94