[EA2B] Paper transport jam in the Finisher (Middle path sensor)
Classification
Paper jam in finisher section
MJ-1032
Probable cause
2nd transport motor (M4)
abnormality
Entrance path sensor (S19)
abnormality
Middle path sensor (S7)
abnormality
Faulty cables and connectors
Finisher control PC board
(FIN) abnormality
[EA2C] Paper transport jam in the Finisher (Entrance path - sub-path sensor)
Classification
Paper jam in finisher section
MJ-1032
Probable cause
1st transport motor (M8)
abnormality
2nd transport motor (M4)
abnormality
Entrance path sensor (S19)
abnormality
Sub-path sensor (S8)
abnormality
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
Paper transport jam in the Finisher (Middle path sensor)
Checking and measures
Check if the electrical continuity of the coil is normal. If electricity is
not conducted, replace the motor.
Measure the voltage on TP86 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Measure the voltage on TP84 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector.
(Finisher control PC board (FIN): CN6, CN14, CN22)
If the error still occurs after replacing the sensor and the connector,
replace the finisher control PC board (FIN).
Paper transport jam in the Finisher (Entrance path - sub-path
sensor)
Checking and measures
Check if the electrical continuity of the coil is normal. If electricity is
not conducted, replace the motor.
Check if the electrical continuity of the coil is normal. If electricity is
not conducted, replace the motor.
Measure the voltage on TP86 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Measure the voltage on TP85 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
8 - 124
Error content
Error content
© 2015 TOSHIBA TEC CORPORATION All rights reserved