[D] 3. SRAM Re-Initialize Support
Since an F900 error cannot be cleared in the 3C mode, use this function to clear the error in the
following cases:
•
When the SRAM board (for the SYS board) and the SYS board are replaced at the same time
•
When the SRAM is initialized with wrong destination at the replacement of the SRAM board
•
After updating with a download jig and performing Clear SRAM, select this item.
•
After selecting this, initialize SRAM following its replacement procedure.
Refer to P. 9-25 "9.2.8 Precautions and procedure when replacing the SRAM".
5.17 Password Reset Mode
The administrator password and the service password can be reset.
* Once the password is reset, user data will be deleted.
<Operation procedure>
Password
[HA]
input
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SELF-DIAGNOSTIC MODE
[OK]
[OK]
[OK]
5 - 54
[POWER] OFF
© 2015 TOSHIBA TEC CORPORATION All rights reserved