Toshiba e-STUDIO2008A Service Manual page 703

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2008A:
Table of Contents

Advertisement

[C290] Scanner fuse blowout (e-STUDIO207L/257/307/357/457/507)
Classification
Scanning system related
service call
Check item
Is 24V supplied to the SYS
board?
Parts to be replaced
SYS board
Fuse
LVPS
Harness
© 2015 TOSHIBA TEC CORPORATION All rights reserved
Power is not supplied to the scanner due to its power fuse blowout
and it does not operate
Result
Yes
Check the following because the 24V check signal on
the SYS board is abnormal:
1. Check if there is any abnormality in the parts
mounted on the SYS board.
2. Check if 3V is input in Pin 35 of the scanner CPU
(IC15) of the SYS board.
3. Replace the SYS board.
No
1. Check if the supply harness (CN130) is connected
properly.
2. Check if 24V and SG on the SYS board are short
circuited.
3. Check if the power supply is not short circuited by
disconnecting the supply harness (CN130) on the
SYS board.
4. Check if the fuse on the switching power supply
(LVPS) is open circuited.
5. Replace the fuse.
6. Replace the supply harness.
8 - 165
Error content
Measure
Remark
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING