[G] Right margin
<Procedure>
Performs FS-05.  (05 Adjustment Mode)
(1)
(2)
Open the original cover or RADF.
Press [TEST COPY]  [START] to make a copy at the mode of A3/LD, 100%, Text/Photo and
(3)
the lower drawer (Refer to *).
(4)
Measure the blank area F at the right side of the copied image.
(5)
Check if the blank area F is within the range of 4.2 ± 1.0 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
FS-05  Key in the code [4052]  [START]
 (Key in a value (acceptable values: 0 to 255))
 Press the [OK] button (stored in memory).
 ("100% A" is displayed.)
* The larger the adjustment value is, the wider the blank area at the right side becomes
(approx. 0.04 mm/step).
© 2015 TOSHIBA TEC CORPORATION All rights reserved
Feeding direction
F
Fig.6-17
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
6 - 21
SETTING / ADJUSTMENT