4.7.11
Recovery blade
(1)
Remove the drum separation finger units.
( P. 4-96 "4.7.10 Drum separation finger")
(2)
Remove 2 screws, and take off the whole
recovery blade [1] with the bracket.
Notes:
When cleaning the inside of the cleaner unit,
be careful of the following in order not to
damage the films [3] attached on the toner
recovery auger [2]:
1. Do not use an air blower for cleaning.
(Use a vacuum cleaner.)
2. When using a vacuum cleaner, be careful
not to hit the nozzle of the vacuum
cleaner to the films [3].
3. When rotating the toner recovery auger
[2], rotate it only in the same direction as
that for transporting toner.
© 2015 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-259
Fig. 4-260
Fig. 4-261
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
4 - 97
DISASSEMBLY AND REPLACEMENT
4