6.7.2
Adjustment of image density
The image density level can be set at the following codes.
Code
7595-0 to 4
Adjustment of image density
<Procedure>
(1)
Performs FS-05.
(2)
Key in the code and press the [START] button.
(3)
Key in the sub code and press the [START] button.
(4)
Key in an adjustment value.
(To correct the keyed-in value, press the button.)
(5)
Press the [OK] button to store the value in memory. The equipment goes back to the ready state.
(6)
For resetting the value, repeat step (2) to (5).
(7)
Turn the power OFF.
<Confirmation>
Check the beam level conversion setting with the actual fax data received, if possible.
© 2015 TOSHIBA TEC CORPORATION All rights reserved
Item to be adjusted
6 - 41
< 05 Adjustment Mode >
Remarks
When the value is decreased, text becomes lighter.
Acceptable values: 0 to 10
Notes:
1. Set not to reverse the large and small
number of the setting value corresponding
to the sub code.
Ex.) When the image density level for 7595-
0, 7595-1, 7595-2, 7595-3, and 7595-4 is
assumed to be "A", "B", "C", "D", and "E"
respectively, they should have the following
correlation:
2.
A
B
C
D
E
Remember that the image specifications
and life span of the replacing parts may not
meet the standard when the setting value is
changed from the default value.