Adjusting the Horizontal Head-to-Head Calibration

If adjustment is required for horizontal Head-to-Head, adjust the values
as follows:
1. With the display set at
press SELECT and then the UP ARROW or DOWN ARROW to
select the alignment value matching the best horizontal alignment
in the horizontal print out.
2. Once the matching alignment value is reached, press SELECT to
save the setting.
3. If adjustment is required for vertical Head-to-Head, proceed to
Section 12.2.
If no adjustment is required for vertical Head-to-Head, press
MENU and press SELECT again. The plotter will print a new set
of three patterns. The new head-to-head pattern will reflect the
latest settings which you have chosen.
"CURRENT HEADS" printout is properly aligned. If it is still not
satisfactory, repeat the adjustment until satisfactory results are
obtained. Then proceed to Section 13.0.
CADJET 2
CALIBRATION
HORIZONTAL=X
Calibration
(X = current alignment value)
Make sure that the
6-55