Fast Deadband (Height Calibration) - ENCAD CADJET 2 Service Manual

Table of Contents

Advertisement

Calibration
11.2

Fast Deadband (Height Calibration)

The FAST DEADBAND (also called the HEIGHT CALIBRATION)
shows the region-dependent Carriage height at 16 regions across the
Platen with the values shown in mils, or 1/1000s of an inch. This value
is displayed on both the menu and on paper.
1. Press the DOWN ARROW once. The display will read:
2. Press SELECT. The plotter will print two fast deadband patterns
with the speed and height values in 16 regions in two consecutive
rows.
speed than the upper row of deadband. Therefore, if the upper
row segments are aligned and acceptable, the lower row
segments will also be as good or better in the alignment with each
other. Record this value in Part 3 of the Calibration Worksheet.
6-50
CALIBRATION
DEADBAND=XX
The lower row of deadband will be printed at a slower
CADJET 2

Advertisement

Table of Contents
loading

Table of Contents