No Movement In The Carriage Axis - ENCAD CADJET 2 Service Manual

Table of Contents

Advertisement

11.4

No Movement in the Carriage Axis

1. Is power applied to the plotter?
2. Is the front panel display ON?
If NO:
If YES: Is the CARRIAGE AXIS FAILURE message displayed?
CADJET 2
a.
Check the Keypad cable's connection (J1) to the
Main Printed Circuit Board. Be certain that it is fully
seated. See Chapter 5, Section 6.2.
b.
Disconnect
the
connector
on
Sections 4.1 and 4.2.) and check for voltage coming
out of the Power Cable. If there is voltage, the fuse
on the Power Supply is good. If there is not voltage,
you need to check the fuse (Step d below).
c.
Check for voltages at the Main Printed Circuit
Board.
d.
Turn power off and disconnect the power cord.
Check the fuse on the Power Supply.
Chapter 5, Section 9.0. Use only a 250 Volt 2 Amp
Fast Blow fuse, 5mm x 20mm. (Be careful not to
mistakenly use a 32 Volt fuse.)
a.
Turn off the plotter and then turn it on again to see if
the same message appears.
If YES: Make sure that nothing is blocking the
movement of the Carriage Assembly. Turn
off the plotter and move the Carriage
Assembly from left to right to make sure it
moves freely.
Troubleshooting
Power Cable
from
the
MPCB
(see
the JP1
Chapter 5,
See
4-31

Advertisement

Table of Contents