Troubleshooting

11.15 Plotter is Noisy

1. Noisy operation may be caused by a dirty Slide Shaft. Refer to the
"Slide Shaft Maintenance" procedures in Chapter 3, Section 3.0.
2. Check for tightness of the Roller Supports by tightening the
hardware. See Chapter 6, Section 8.2
3. The Lower Drive Shaft Rollers may be misaligned.
4. The Fan Assembly may have something that has fallen into it or it
may need to be replaced. Remove the Fan Assembly first to see
if anything is loose inside of it.
Assembly. See Chapter 5, Section 11.0.

11.16 User Parameters Not Saved When Power Is Cycled

If the user parameters are not as expected when the plotter is turned
on, the parameters were not saved by pressing SELECT before
turning off the plotter. Go to the desired menu and display the desired
menu parameter.
equals sign (=) is flashing, press the SELECT button to save. Save
the desired default settings to "USER1." This User number will be
used when the plotter is powered up.
4-58
If not, then replace the Fan
While this value or setting is displayed and the