2.
Inspect for runout.
Standard:
0.02 mm (0.001 in) max.
Service Limit: 0.05 mm (0.002 in)
NOTE: Support the mainshaft at both ends as
shown.
Rotate two complete revolutions.
If the runout exceeds the service limit, replace the
mainshaft with a new one.