Main Menu
Roof
Roof Side Seal/Retainer Replacement
9. If the old roof side retainer is to be reinstalled, glue
the new EPT sealer to it as shown.
NOTE: Be careful not to touch the roof side retainer
where the EPT sealer will be applied.
EPT SEALER
Length: 15 mm (0.59 in)
Width: 25 mm (0.98 in)
Thickness: 5 mm (0.2 in)
EPT SEALER
Length: 75 mm (3.0 in)
Width: 10 mm (0.39 in)
Thickness: 3 mm (0.1 in)
10. If the old roof side seal is to be reinstalled, scrape
the old butyl tape from each end of it, then clean
each end with alcohol. Glue the new butyl tape on
each end as shown.
Butyl tape thickness: 0.5 mm (0.02 in)
BUTYL
TAPE
20 mm (0.79 in)
15 mm
3 mm
(0.59 in)
(0.1 in)
ROOF SIDE
> SEAL
(Rear portion)
Table of Contents
EPT SEALER
Length: 445 mm (17.5 in)
Width: 10 mm (0.39 in)
Thickness: 10 mm (0.39 in)
ROOF SIDE
RETAINER
ROOF SIDE
SEAL
(Front portion)
TAPE
15 mm
(0.59 in)
3 mm
(0.1 in)
11. Install the roof side retainer.
NOTE:
• Be careful not to touch the roof side retainer
where sealant will be applied.
• Align each end of the roof side retainer with the
roof corner edges.
Screw locations, 3
Align.
12. Glue the new EPT sealer on the roof as shown.
EPT sealer thickness: 3.0 mm (0.12 in)
Front:
20 mm
(0.79 in)
Rear:
BUTYL
ROOF
20 mm
20 mm
(0.79 in)
(0.79 in)
ROOF SIDE
RETAINER
EPT
SEALER
10 mm
ROOF SIDE
(0.39 in)
HOOK
EPT
SEALER
Align.
ROOF
30 mm
(1.2 in)
5 mm (0.2 in)
30 mm
(1.2 in)