Mainshaft Assembly
Inspection
1.
Inspect the gear surface and bearing surface for
wear and damage, then measure the mainshaft at
points A, B, and C.
Standard:
A (Ball bearing surface):
B (Needle bearing surface): 42.984—43.000 mm
C (Ball bearing surface):
Service limit:
A: 31.950 mm (1.2579 in)
B: 42.930 mm (1.6902 in)
C: 30.930 mm (1.2177 in)
Inspect oil passages for clogging.
Inspect for wear and damage.
If any part of the mainshaft is less than the service
limit, replace it with a new one.
32.002—32.018 mm
(1.2599-1.2605 in)
(1.6923-1.6929 in)
30.984-31.000 mm
(1.2198-1.2205 in)