Defective part
Main PWB
6
3. DP-scanning second (back) page
Defective part
DP_CIS unit
1
DP_SHD PWB
2
DP_CIS
3
Main PWB
4
Service Manual
Check description
The main PWB is defective.
Check description
Check the location the CIS unit
is mounted.
Check the CIS and the SHD
PWB is properly connected.
CIS is defective.
The main PWB is defective.
Replace the main PWB.(see page 1-5-74)
Re-mount the CIS unit if it is hanged off.
Reinsert the connector if the PWB was loosely
inserted.If not cured, replace the PWB.
Replace the CIS and perform U091 and U411.
(see page 1-3-65,1-3-152)
Replace the main PWB.(see page 1-5-74)
1-4-166
Corrective Action
Corrective Action
2N8/2N7
Y116520-