(2) Table of general classification
Error code
U00000
No response or busy after the set number of redials.
U00100
Transmission was interrupted by a press of the stop/clear key.
U00200
Reception was interrupted by a press of the stop/clear key.
U00300
Recording paper on the destination unit has run out during transmission.
U004XX
A connection was made but interrupted during handshake with the receiver unit (refer to
P.1-4-248 U004XX error code table).
U006XX
Communication was interrupted because of a machine problem (refer to P.1-4-248
U006XX error code table).
U00700
Communication was interrupted because of a problem in the destination unit.
U008XX
A page transmission error occurred in G3 mode (refer to P.1-4-248 U008XX error code
table).
U009XX
A page reception error occurred in G3 mode (refer to P.1-4-248 U009XX error code
table).
U010XX
Transmission in G3 mode was interrupted by a signal error (refer to P.1-4-249 U010XX
error code table).
U011XX
Reception in G3 mode was interrupted by a signal error (refer to P.1-4-250 U011XX error
code table).
U01400
An invalid one-touch key was specified during communication.
U01500
A communication error occurred when calling in V.8 mode.
U01600
A communication error occurred when called in V.8 mode.
U017XX
A communication error occurred before starting T.30 protocol during transmission in V.34
mode (refer to P.1-4-251 U017XX error code table).
U018XX
A communication error occurred before starting T.30 protocol during reception in V.34
mode (refer to P.1-4-251 U018XX error code table).
U03000
No document was present in the destination unit when polling reception started.
U03200
In interoffice subaddress-based bulletin board reception, data was not stored in the box
specified by the destination unit.
U03300
In polling reception from a unit of our make, operation was interrupted due to a mismatch
in permit ID or telephone number. Or, in interoffice subaddress-based bulletin board
reception, operation was interrupted due to a mismatch in permit ID or telephone num-
ber.
U03400
Polling reception was interrupted because of a mismatch in individual numbers (destina-
tion unit is either of our make or by another manufacturer).
U03500
In interoffice subaddress-based bulletin board reception, the specified Subaddress confi-
dential box number was not registered in the destination unit.
U03600
An interoffice subaddress-based bulletin board reception was interrupted because of a
mismatch in the specified subaddress confidential box number.
U03700
Interoffice subaddress-based bulletin board reception failed because the destination unit
had no subaddress-based bulletin board transmission capability, or data was not stored
in any subaddress confidential box in the destination unit.