(8) Detaching and refitting the operation PWB
Procedure
1. Unhook two hooks and then remove the
operation hinge cover A.
2. Remove two screws of the operation
rear lid.
3. Unhook four hooks and then remove
the operation rear lid.
Y116520-3
Operation hinge cover A
Hooks
Operation rear lid
Screw
1-5-91
Operation hinge cover A
Figure 1-5-143
Screw
Operation rear lid
Hooks
Figure 1-5-144
Service Manual
2N8/2N7
Hooks