Connector
Pin
YC6
1
Connected to
2
feed PWB 1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Y116520-3
Signal
GND
JOB_SET
JOB_MOT_REM
JOB_MOT_CLK
JOB_MOT_DIR
JOB_OPEN_SENS
JOB_SOL_REM
GND
MAIN_HEAT_REM
PRESS_REM
ZEROC
FSR_RELAY
PRESS_REM
EXIT_REAR_FAN_
L
EXIT_REAR_FAN_
H
GND
GND
FSR_MOT_REM
FSR_MOT_CLK
FSR_MOT_RDY
FSR_MOT_DIR
FSR_MOT_BARKE
GND
MPF_TABLE
MPF_WID1
MPF_WID2
MPF_WID3
MPF_LNG
GND
MPF_PPR
MPF_UP
MPF_DOWN
MPF_JAM
MPF_CL
I/O
Voltage
-
-
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC (pulse) JSEM clock signal
O
0/3.3 V DC
I
0/3.3 V DC
O
0/24 V DC
-
-
-
-
O
0/3.3 V DC
O
0/3.3 V DC (pulse) Zero-cross signal
O
0/3.3 V DC
-
-
O
0/24 V DC
O
0/24 V DC
-
-
-
-
O
0/3.3 V DC
0/3.3 V DC (pulse) FUM clock signal
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
0/24 V DC
2-3-15
Description
Ground
Job separator set signal
JSEM: On/Off
JSEM drive switch signal
JSOCS: On/Off
JSFSSOL: On/Off
Ground
Not used
Fuser heater remote signal
Fuser relay signal
Not used
ERFM: On/Off
ERFM: On/Off
Ground
Ground
FUM: On/Off
FUM ready signal
FUM drive switch signal
FUM brake signal
Ground
MPTSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPLSW: On/Off
Ground
MPPS: On/Off
MPLS1: On/Off
MPLS2: On/Off
MPFS: On/Off
MPPFCL: On/Off
2N8/2N7