Item No.
U034
Adjusting the print start timing
Description
Adjusts the leading edge registration or center line.
Purpose
Make the adjustment if there is a regular error between the leading edges of the copy image and
original.
Make the adjustment if there is a regular error between the center lines of the copy image and
original.
Method
1. Press the start key.
2. Select the item to be adjusted.
LSU Out Top
LSU Out Left
Mode
Reset
On Timing
Off Timing
*: 75 ppm model only.
Service Manual
Display
Leading edge registration adjustment
Center line adjustment
Sets the conveying timing verification mode.
Resets the conveying timing verification data.
Verify the conveying timing (sensor on).
Verify the conveying timing (sensor recovery).
Description
Description
1-3-36
2N8/2N7
Y116520-