(2) Detaching and refitting fuser IH unit
Procedure
1. Remove the rear upper cover and the
rear lower cover (see page 1-5-3).
2. Remove the fuser unit (see page 1-5-
67).
3. Remove the right upper cover (see
page 1-5-9).
4. Remove the right middle rear cover
(see page 1-5-9).
5. Remove four screws and then remove
the fuser IH PWB cover (see page 1-5-
10).
6. Remove the IH wire cover (see page 1-
5-10).
7. Remove three wire holders.
8. Release two wire saddles.
9. Remove two connectors from the fuser
IH PWB according to the following
notes.
*: Confirm the power plug is removed
from the outlet without fail when you
remove the connector because a high
current is supplied to fuser IH unit by
this connector.
*: Confirm the connected connector was
surely locked when you connect this
connector again.
Y116520-3
Wire holder
Wire holders
Figure 1-5-114
1-5-69
Fuser IH PWB
Connectors
Wire saddles
Fuser IH
PWB
Service Manual
2N8/2N7