Item No.
U071
Adjusting the DP scanning timing
Description
Adjusts the DP original scanning timing.
Purpose
Make the adjustment if there is a regular error between the leading or trailing edges of the origi-
nal and the copy image when the DP is used.
Method
1. Press the start key.
2. Press the system menu key.
3. Place an original on the DP and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.l
Display
Front Head
Front Tail
CIS Head
CIS Tail
Service Manual
Description
Description
Leading edge registration of
CCD (first side)
Trailing edge registration of
CCD (first side)
Leading edge registration of
CIS
Trailing edge registration of CIS -19 to 19
1-3-58
Setting
Initial
range
setting
-19 to 19
0
-19 to 19
0
-19 to 19
0
0
2N8/2N7
Change in
value per step
0.207 mm
0.207 mm
0.207 mm
0.207 mm
Y116520-