Olivetti d-Copia 6500MF Plus Service Manual page 276

Multifuction digital copier
Table of Contents

Advertisement

Item No.
U411
7. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning ( P.1-3-159).
* : If the target values are not obtainable automatically, manually enter the following target
values in the following manner and perform adjustment.
1. Enter the target values which are shown at the bottom of the chart1 original
(P/N: AVGR14938B) executing maintenance item U425.
2. Set a chart1 original on the platen.
3. Enter maintenance item U411.
4. Select [Target].
5. Select [U425] and press the start key.
6. Select [Table (Chart1)].
7. Select the item.
* : Select All for normal use.
8. Press the start key. Auto adjustment starts.
Method: [DP FaceUp (Chart1)]
To perform adjustment on the first side of the DP using Chart 1.
To automatically enter the target value.
1. Set a chart1 original (P/N: AVGR14938B) on the DP face up.
2. Enter maintenance item U411.
3. Select [Target].
4. Select [Auto] and press the start key.
5. Select [DP FaceUp (Chart1)].
6. Select [Input].
Input
7. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning ( P.1-3-159).
Service Manual
Display
Executing the adjustment for input gamma and matrix
Description
Description
1-3-154
2N8/2N7-3
Y116520-