Item No.
U464
Setting: [Leaving Time]
1. Change the setting value using the +/- keys or numeric keys.
Display
Time(min)
2. Press the start key. The value is set.
Setting: [Driving Time]
1. Change the setting value using the +/- keys.
Display
Time(sec)
2. Press the start key. The value is set.
Setting: [Timing]
1. Change the setting value using the +/- keys.
Display
Time(sec)
2. Press the start key. The value is set.
Setting: [Target Value]
1. Select the item.
2. Change the setting value using the +/- keys or numeric keys.
Display
Thick-
ness(K)
Gamma(K)
3. Press the start key. The value is set.
Method: [Calib]
1. Select [Execute].
2. Press the start key. Calibration is executed.
* : Duplicates selecting [System Menu] - [Adjustment/Maintenance] - [Calibration].
The same operation as System menu.
Completion
Press the stop key.
* : The screen for selecting a maintenance item No. is displayed.
Y116520-3
Description
Setting the standard time of sleep mode
Description
Setting the drive standard time
Description
Setting the drive standard time of con-
tinuous print
Description
Toner thick layer calibration
Light amount calibration
1-3-177
Description
300 to 3000 (s)
0 to 3600 (s)
Setting
range
0 to 1000 145
330
0 to 500
2N8/2N7-4
Initial
Setting range
setting
0 to 480 (min)
60
Initial
Setting range
setting
300
Initial
Setting range
setting
0
Initial setting
65ppm
80ppm
145
330
Service Manual