8130
DF shift release motor error
When the DF shift release
motor is driven, DF shift
release sensor does not turn
on within 1 s.
Y116520-3
Related parts
DF shift release
motor
DF shift release
sensor
DF main PWB
Replace the DF main PWB (Refer to the
service manual for the document finisher).
1-4-127
Check procedures/
corrective measures
1. Check that cancelling the maintenance
mode after executing U240 Motor - Sort
for the finisher operation check lets the
rear and forth cursors return to the home
position (see page 1-3-116).
2. Manipulate the front and rear shift guide
to check it is smoothly operable.
3. Check that the drive from the motor
reaches the shift guide front and rear.
4. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF shift release motor and DF main
PWB (YC14)
5. If the wiring is disconnected, shorted or
grounded, replace the wiring.
6. Replace the DF shift release motor.
1. Execute U241 Finisher - Shift Unlock HP
to check the finisher switch (see page 1-
3-118).
2. Check that the sensor and its mounting
bracket are correctly positioned.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF shift release sensor and DF main
PWB (YC23)
4. Replace the DF shift release sensor.