Connector
Pin
YC1
32
Connected to
33
engine PWB
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
Y116520-3
Signal
MPF_JAM
MPF_LIFT_DOWN
MPF_LIFT_UP
MPF_PPR_SET
GND
MPF_LNG
MPF_WID3
MPF_WID2
MPF_WID1
MPF_TABLE
GND
FSR_MOT_BRK
FSR_MOT_DIR
FSR_MOT_RDY
FSR_MOT_CLK
FSR_MOT_REM
GND
GND
EXIT_REAR_FAN_
H
EXIT_REAR_FAN_
L
PRESS_REM
FSR_RELAY
ZEROC
PRESS_REM
MAIN_HEAT_REM
GND
JOB_SOL_REM
JOB_OPEN_SENS
JOB_MOT_DIR
JOB_MOT_CLK
JOB_MOT_REM
JOB_SET
GND
I/O
Voltage
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC (pulse) FUM clock signal
I
0/3.3 V DC
-
-
-
-
I
0/24 V DC
I
0/24 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC (pulse) Zero-cross signal
I
0/3.3 V DC
-
-
-
-
I
0/24 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC (pulse) JSEM clock signal
I
0/3.3 V DC
O
0/3.3 V DC
-
-
2-3-53
Description
MPFS: On/Off
MPLS2: On/Off
MPLS1: On/Off
MPPS: On/Off
Ground
MPPLSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPTSW: On/Off
Ground
FUM break signal
FUM drive switch signal
FUM ready signal
FUM: On/Off
Not used
Ground
ERFM: On/Off
ERFM: On/Off
Not used
Fuser relay signal
Fuser heater remote signal
Not used
Ground
JSFSSOL: On/Off
JSOCS: On/Off
JSEM drive switch signal
JSEM: On/Off
Job separator set signal
Ground