Olivetti d-Copia 6500MF Plus Service Manual page 293

Multifuction digital copier
Table of Contents

Advertisement

Item No.
U425
2. Measure the distance from the leading edge to the top of black belt 1 of the original at A, B
and C.
Measurement procedure
1) Measure the distance from the leading edge to the top of black belt 1 of the original at A
(30 mm from the left edge), B (148.5 mm from the left edge) and C (267 mm from the left
edge), respectively.
2) Apply the following formula for the values obtained: ((A + B + C) / 3)
3. Enter the values solved using the cursor left/right keys or numeric keys in [Dist1].
4. Press the start key. The value is set.
5. Measure the distance from the left edge to the right edge black belt 2 of the original at F.
Measurement procedure
1) Measure the distance from the left edge to the right edge black belt 2 of the original at F
(15 mm from the top edge of black belt 1).
6. Enter the values using the cursor left/right keys or numeric keys in [Dist2].
7. Press the start key. The value is set.
8. Measure the distance from the top edge of black belt 1 to the bottom of black belt 3 of the
original at D and E.
1) Measure the distance from the top edge of black belt 1 to the bottom of black belt 3 of the
original at D (30 mm from the left edge) and E (267 mm from the left edge), respectively.
2) Apply the following formula for the values obtained: (D/2 + E/2)
9. Enter the measured value using the cursor left/right keys or numeric keys in [Dist3].
10. Press the start key. The value is set.
Leading edge
Left edge
35 mm
110 mm
185 mm
Y116520-3
30 mm
A
Black
belt (a)
D
Black
belt (b)
E
F
Original for adjustment (P/N: AVGR05131K)
Description
148.5 mm
B
G
Figure 1-3-57
1-3-171
267 mm
C
Black
belt (c)
[Lead] =
((A + C) / 2 + B) / 2
[Main Scan] =
((D + F) / 2 + E) / 2
[Sub Scan] = G
Service Manual
2N8/2N7-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 8000mf plus

Table of Contents