Item No.
U325
Setting the paper interval
Description
Due to the fact that, if toner consumption per driving time drastically lowers, the variation in color-
ing and low density and gray background become prominent, the print coverage that executes
toner ejection according to the low density at a continued vertical printing with the low coverage
data must be changed.
Purpose
The settings must be changed when printing an extensive volume with the vertical A4/Letter of
low coverage contents or the toner consumption per driving time is extremely low.
Method
1. Press the start key.
2. Select the item to set.
Interval
Mode
Setting: [Interval]
1. Select On or Off.
On
Off
Initial setting: Off
2. Press the start key. The setting is set.
Setting: [Mode]
1. Change the setting value using the +/- keys or numeric keys.
Display
Mode
* : Mode 1 or Mode 2 is effective when Interval is on.
Mode 1: For usages where the original date includes a low toner coverage or gray back-
ground is observed (T7 threshold is 3%).
Mode 2: For environments where printing is seldom made but the machine toggles in
warm-up mode. (Mostly scanning is used such as in a show room.)
(T7 threshold 3% + simplified refreshing is implemented after the warm-up calibration)
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Y116520-3
Display
On-Off control of Inter-paper toner ejection
Setting mode of Inter-paper toner ejection
Display
Inter-paper toner ejection is performed
Inter-paper toner ejection is not performed
Inter-paper toner ejection mode