5. Pull the paper conveying unit out.
6. Remove two screws and then open the
front middle cover.
7. Lock the developer waste exit that has
been released (see page 1-2-25).
8. Remove the screw and then open the
connector cover.
9. Remove the connector.
10. Release the wire saddle.
11. Remove four fixed screws of inner unit.
Service Manual
Connector cover
Screw
Front middle
cover
Screw
Inner unit
Inner unit
Screws
1-5-54
Connector
Wire saddle
Figure 1-5-91
Figure 1-5-92
2N8/2N7
Screw
Screw
Screw
Y116520-3