Connector
Pin
YC1
1
2
Connected to
Power
source PWB
YC4
1
Connected to
2
engine PWB
3
4
5
6
YC5
1
Connected to
2
fuser heater
3
and fuser-
4
thermostat 2
5
YC6
1
Connected to
2
fuser thermo-
stat 1
YC8
1
Connected to
2
feed PWB 1
3
4
5
6
7
8
YC9
1
Connected to
Fuser IH
YC10
1
Connected to
Fuser IH
Y116520-3
Signal
I/O
LIVE
NEUTRAL
SGAND
Vcc
IH_REM
ROTATION
RXD
TXD
LIVE_OUT
NEUTRAL_OUT
NEUTRAL_OUT
+15V1
+15V2
FSR_RELAY_24V
+24V1
FSR_RELAY
GND
GND
ZEROC
+24V2
PRESS_REM
VS
COIL_COM
Voltage
I
220-240 V AC
I
220-240 V AC
-
-
I
3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC (pulse) FIH control signal
I
0/3.3 V DC (pulse) Serial communication data signal
O
0/3.3 V DC (pulse) Serial communication data signal
O
220-240 V AC
-
-
O
220-240 V AC
-
-
O
15 V DC
I
15 V DC
I
0/3.3 V DC
I
24 V DC
I
0/3.3 V DC
-
-
-
-
-
-
I
24 V DC
I
0/3.3 V DC
O
138 V to 370 V AC Resonant circuit output to the IH coil
O
138 V to 370 V AC Resonant circuit output to the IH coil
2-3-3 3
Description
220-240 V AC power input
220-240 V AC power input
Ground
3.3 V DC power from EPWB
FIH: On/Off
AC power output to FTS2
Not used
AC power output to FH
Not used
15V DC power to FTS1
15V DC power from FTS1
Fuser relay signal
24 V DC power from feed PWB 1
Fuser relay signal
Ground
Ground
Not used
24 V DC power from feed PWB 1
Fuser heater remote signal