Code
Contents
2201
drum motor steady-state
error
After drum motor is stabilized,
the ready signal is at the H
level for 1 s continuously.
2211
Drum motor startup error
Drum motor is not stabilized
within 2 s since the motor is
activated.
Y116520-3
Related parts
Drum unit
Drum motor
Engine PWB
Drum unit
drum motor
Engine PWB
1-4-79
Check procedures/
corrective measures
1. Confirm that the drum or the drum screw
can rotate.
2. If it won't rotate, replace the drum unit.
(see page 1-5-57)
1. Check the drive gear can rotate or they
are not unusually loaded and, if neces-
sary, replace.
2. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
drum motor and Feed PWB 1 (YC9)
Feed PWB 1 (YC2) and Engine PWB
(YC5)
3. If the wiring is disconnected, shorted or
grounded, replace the wiring.
4. Replace the drum motor (see page 1-5-
102).
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
83).
1. Check the drive gear can rotate or they
are not unusually loaded and, if neces-
sary, replace.
2. Confirm that the drum or the drum screw
can rotate.
3. If it won't rotate, replace the drum unit
(see page 1-5-57).
1. Confirm that the wiring connector is
firmly connected and, if necessary, con-
nect the connector all the way in.
drum motor and Feed PWB 1 (YC9)
Feed PWB 1 (YC2) and Engine PWB
(YC5)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the drum motor (see page 1-5-
102).
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
83).
2N8/2N7