8090
DF paddle motor error
When the DF paddle motor is
driven, DF paddle sensor
does not turn on within 1 s.
Y116520-3
Related parts
DF paddle motor
DF paddle sensor
DF main PWB
Replace the DF main PWB (Refer to the
service manual for the document finisher).
1-4-123
Check procedures/
corrective measures
1. Execute U240 Motor - Beat to check the
finisher operation (see page 1-3-116).
2. Check that the paddle can rotate.
3. Check that the drive from the motor
reaches the paddle.
4. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF paddle motor and DF main PWB
(YC15)
5. If the wiring is disconnected, shorted or
grounded, replace the wiring.
6. Replace the DF paddle motor.
1. Execute U241 Finisher - Bundle Eject
HP to check the finisher switch (see
page 1-3-118).
2. Check that the sensor and its mounting
bracket are correctly positioned.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF paddle sensor and DF main PWB
(YC22)
4. Replace the DF paddle sensor.
2N8/2N7