5. The CCD unit Height Adjustment 1
In case a part of the image is whitish from the leading edge or the background image appears like the
illustration "a".
The replacement ISU comes complete with a
large spacer (B) and a small spacer (C).
1. Set the spacer (large) (B) into the out-
side screw holes at the CCD sensor
side.
2. Check the image.
3. In case of no problem on the image, go
to "9. Image Adjustment".
4. In case of the problem on the image, go
to "6. Re-adjustment 1".
6. Re-adjustment 1
1. In case the whitish or background
image still appears.
c: Insert the additional spacer (small) (C)
2. In case the white vertical lines appear.
d: Remove the spacer (large) (B) and insert the
spacer (small) (C).
Check the image and go to "9. Image Adjust-
ment".
Y116520-3
ISU(CCD unit)
A
Spacer (large)
Figure 1-5-77
Figure 1-5-78
c
d
Figure 1-5-79
1-5-47
2N8/2N7
B
C
Spacer (small)
B
B
C
B
C