1-5-7 Fuser section
(1) Detaching and refitting the fuser unit
Procedure
1. Pull the paper conveying unit out.
2. Remove the screw and then the fuser
wire cover.
3. Remove two connectors
Y116520-3
Connector
1-5-67
Connector
Fuser wire cover
Paper
conveying unit
Figure 1-5-112
Service Manual
2N8/2N7
Screw