5. Remove the connector and the band of
PF paper feed motor.
6. Remove the connector (YC15) from the
PF main PWB and then release the
wire from two wire saddles.
7. Remove four screws and then remove
the PF drive unit.
8. Check or replace the PF drive unit and
refit all the removed parts.
Service Manual
Connector
Band
PF main PWB
Wire saddles
PF drive unit
Screws
Screw
Screw
Screw
1-5-112
YC15
PF main PWB
Figure 1-5-183
Screw
Screw
Figure 1-5-184
2N8/2N7
Screw
Y116520-3