Code
Contents
6950
Fuser IH PWB communica-
tion error
No response is received in 30
ms since a command is sent
to IHCPU.
A checksum error is detected
10 times in succession.
6960
Current PWB error
The power current is greater
than 1A for 5 seconds contin-
uously despite that 500W was
indicated as the fuser power
during power-up.
* : 220-240 V model only
Service Manual
Related parts
Power source PWB
Feed PWB 1
Fuser IH PWB
Engine PWB
Current PWB
1-4-108
Check procedures/
corrective measures
1. Confirm that the wiring connector is
firmly connected and, if necessary, con-
nect the connector all the way in.
Power source PWB (YC9) and Feed
PWB 1(YC4)
Power source PWB (YC3) and Fuser IH
PWB (YC1)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. If the +24V output is not given by the
power source PWB (YC9), replace the
power source PWB.
1. Confirm that the wiring connector is
firmly connected and, if necessary, con-
nect the connector all the way in.
Power source PWB (YC3) and Fuser IH
PWB (YC1)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. If the +24V output is not given by the
feed PWB1 (YC27), replace the feed
PWB1.
1. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Fuser IH PWB(YC4) and Engine PWB
(YC26)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the Fuser IH PWB (see page 1-
5-95).
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
83).
1. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Current PWB(YC17) and Feed PWB2
(YC13)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the Current PWB.
2N8/2N7-1
Y116520-