Olivetti d-Copia 6500MF Plus Service Manual page 468

Multifuction digital copier
Table of Contents

Advertisement

Code
Contents
8350
CF side registration motor 1
error
When initial operation, CF
side registration sensor 1
does not turn on within 1 s.
Service Manual
Related parts
CF side registration
motor 1
CF side registration
sensor 1
CF main PWB
Replace the CF main PWB
1-4-140
Check procedures/
corrective measures
1. Execute U240 Booklet - Width Test to
check the finisher operation (see page
1-3-116).
2. Manipulate the side registration lower
guide back and forth to check it can
smoothly operable.
3. Check that the drive from the motor
reaches the side registration lower
guide.
4. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
CF side registration motor 1 and CF
main PWB (YC10)
5. If the wiring is disconnected, shorted or
grounded, replace the wiring.
6. Replace the CF side registration motor
1.
1. Execute U241 Booklet - Width Down HP
to check the finisher switch (see page 1-
3-118).
2. Check that the sensor and its mounting
bracket are correctly positioned.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
CF side registration sensor 1 and CF
main PWB (YC20)
4. Replace the CF side registration sensor
1.
2N8/2N7
Y116520-