Item No.
U906
Resetting partial operation control
Description
Resets the service call code for partial operation control.
Purpose
To be reset after partial operation is performed due to problems in the cassettes or other sec-
tions, and the related parts are serviced.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key to reset partial operation control.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
U908
Checking the total counter value
Description
Displays the total counter value.
Purpose
To check the total counter value.
Method
1. Press the start key. The total count value is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U910
Clearing the print coverage data
Description
Clears the accumulated data for the print coverage per A4 size paper and its period of time (as
shown on the service status report).
Purpose
To clear data as required at times such as during maintenance service.
Method
1. Press the start key.
2. Select [Execute].
3. Press the start key. The print coverage data is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.