U052
Setting: [Loop Sensor Control]
1. Select the item.
2. Select On or Off.
Display
No.1
No.2
No.3
No.4
No.5
No.6
3. Press the start key. The setting is set.
Setting: [Set Loop Sensor Valid]
1. Select On or Off.
Initial setting: On
2. Press the start key. The setting is set.
Completion
Press the stop key. The indication for selecting a maintenance item No. appears.
Service Manual
Description
Determines whether to attempt a correction in the fuser
speed in reference to the transfer-separation speed,
over the length of paper from the leading edge to 30mm.
Determines whether to attempt a correction in the fuser
speed in reference to the transfer-separation speed,
over the length of paper from the leading edge to 30 to
60 mm
Determines whether to attempt a correction in the fuser
speed in reference to the transfer-separation speed,
over the length of paper from the leading edge to 60 to
90 mm
Determines whether to attempt a correction in the fuser
speed in reference to the transfer-separation speed,
over the length of paper from the leading edge to 90 to
120 mm
Determines whether to attempt a correction in the fuser
speed in reference to the transfer-separation speed,
over the length of paper from the leading edge to 120 to
150 mm
Determines whether to attempt a correction in the fuser
speed in reference to the transfer-separation speed,
over the length of paper from the leading edge to 150 to
180 mm
1-3-44
Description
2N8/2N7
Initial setting
65ppm 80ppm
On
On
On
On
On
On
On
On
On
Off
On
Off
Y116520-