(2) Detaching and refitting eject unit
Procedure
1. Remove the job separator (see page 1-
5-71).
2. Remove the screw and then remove the
arm hinge cover A and B.
3. Remove the screw and then remove the
operation mount cover B.
Service Manual
Figure 1-5-117
Operation mount
cover B
Figure 1-5-118
1-5-72
Screw
Arm hinge
cover B
Arm hinge
cover A
Screw
2N8/2N7-2