Minimum Bending Radius For Hybrid Cable - Danfoss VLT ISD 510 Operating Manual

Servo drive system
Hide thumbs Also See for VLT ISD 510:
Table of Contents

Advertisement

VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
Pre-configured hybrid cables are used to connect the ISD 510/DSD 510 servo drives to the Decentral Access Module (DAM 510).
There are 2 types of hybrid cables that are available with both angled and straight M23 connectors:
Feed-in cable for connecting the 1st ISD 510/DSD 510 servo drive of a group to the connection point on the Decentral Access
Module (DAM 510).
Loop cable for connecting the ISD 510/DSD 510 servo drives in daisy-chain format in an application.
Both these cables are provided by Danfoss and are available in various lengths. See the VLT® Servo Drive System ISD 510, DSD 510,
MSD 510 (VLT® Flexmotion
Both ends of the loop cable are fitted with M23 connectors.
The feed-in cable is fitted with an M23 connector at the output end for connection to the 1st ISD 510/DSD 510 servo drive. At the
input end it is pigtailed and the connectors are mounted on the corresponding terminals on the Decentral Access Module (DAM
510).
Table 15: Hybrid Cables
Cable type
Shielded/unshielded
Feed-in cable
Shielded
Loop cable
-
Hybrid cables are available in 2 cross-sections: 2.5 mm
-
See the VLT® Servo Drive System ISD 510, DSD 510, MSD 510 (VLT® Flexmotion
1
VLT® ISD 510 Hybrid xxxx Cable
2
3
Ordering no. 175Gxxxx
4
Specification no. 175Rxxxx Rev. xxx
5
Production: dd.mm.yyyy
6
Length: xxxx
Power rating: 5 x 2.5mm 2 1000V 15A
7
Signal rating: 2 x 0.5mm 2
8
Signal rating Ethernet: 2 x 2 x AWG24 300V
9
1
7
5
G
Illustration 12: Example of a Hybrid Cable Nameplate
1
Cable type
2
Ordering code
3
Revision of specification
4
Manufacturing date
5
Length

3.9.1.1 Minimum Bending Radius for Hybrid Cable

The maximum number of bending cycles is 5 million at 7.5 x cable diameter (15.6 mm).
Permanently flexible: 12 x cable diameter
Permanently installed: 5 x cable diameter
Danfoss A/S © 2020.08
) Design Guide for further information.
Notes
Hybrid cable (overall shield with additional fieldbus and safety section shield).
N O T I C E
300V
8
9
X
X
2
2
(15 A) and 4 mm
(25 A for CE and UL, 20 A for CSA).
) Design Guide for further information.
10
6
Power rating
7
Signal rating
8
Signal rating for Ethernet
9
Barcode
10
Manufacturer logo
System Description
AQ262449648484en-000101 / 175R1135 | 41

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT ISD 510 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Vlt dsd 510

Table of Contents