Danfoss VLT ISD 510 Operating Manual page 209

Servo drive system
Hide thumbs Also See for VLT ISD 510:
Table of Contents

Advertisement

VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
3
4
Illustration 150: STO Input Connector on PSM 510
Table 144: Pin Assignment of STO Connectors on PSM 510
Connec-
Pins
De-
tor name
scrip-
tion
STO PSM
1
STO–
2
STO+
3
STO–
4
STO+
-
Only PELV potential can be connected to the STO inputs.
11.9.9.2 STO Connectors on the DAM 510
11.9.9.2.1 STO Connectors on the Top of DAM 510
There is 1 input and 1 output STO connector on the top of the Decentral Access Module (DAM 510).
Danfoss A/S © 2020.08
Notes
Rating/parameter
Used for STO output
Nominal voltage: 24 V DC ±10%
voltage to the input of
Nominal current: Depends on the number of servo drives in the applica-
the other system
tion.
modules.
Maximum current: 1 A
Conductor cross-section range: 0.2–1.5 mm
Used for STO input
voltage.
N O T I C E
Specifications
2
(AWG 24–AWG 16)
AQ262449648484en-000101 / 175R1135 | 209

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt dsd 510

Table of Contents