13.
In operation block Startup [OB100], check that the module access points have been allocated correctly:
-
Expand Program blocks in the Devices tab.
-
Double-click on Startup [OB100].
-
Type the settings in the screenshot ensuring that the module access points names match the name assigned automati-
cally by TIA. These can be found by opening menu [PLC tags → Show all tags] and then selecting the System constants
tab.
-
14.
Define the input and output telegram address for each system component by creating a tag table:
-
Select menu [PLC tags → FlexMotion], to open the FlexMotion_Telegram window.
-
Define the address of the incoming and outgoing telegram for each system component.
15.
In operation block Synchronous Cycle [OB61], enter the telegram read instructions as per the example below.
Danfoss A/S © 2020.08
Commissioning
AQ262449648484en-000101 / 175R1135 | 129