VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
Possible Causes
•
The sum of the servo drive current exceeds the maximum rating of the DAM 510.
•
The sum of the system modules' current exceeds the maximum rating of the PSM 510.
•
Short on backlink.
Troubleshooting
•
Check the servo drive current consumption.
•
Avoid simultaneous acceleration of all servo drives.
•
Decrease the acceleration value.
9.2.2.5 High Cont. Power Overload (Error 0x2313/0x161)
This fault applies to the PSM 510.
Possible Causes
•
The PSM 510 was operating at over 140% of the nominal power rating for too long.
Troubleshooting
•
Check the current consumption.
9.2.2.6 Continuous Power Overload (Error 0x2314/0x162)
This fault applies to the PSM 510.
Possible Causes
•
The PSM 510 was operating at 100–140% of the nominal power rating for too long.
Troubleshooting
•
Check the current consumption.
9.2.2.7 AUX Overcurrent (Error 0x2391/0x125)
This fault applies to the DAM 510.
Possible Causes
•
The servo drives are consuming more power on the U
Troubleshooting
•
Check the number of attached servo drives with the shell diagrams in the VLT® Servo Drive System ISD 510, DSD 510, MSD 510
(VLT® Flexmotion
) Design Guide.
™
•
Avoid simultaneous lifting of the servo drive brakes.
9.2.2.8 AUX Overvoltage (Error 0x3292/0x133)
This fault applies to the DAM 510.
Possible Causes
•
Incorrect U
supply.
AUX
Troubleshooting
•
Check that the supply matches the auxiliary supply requirements.
9.2.2.9 AUX Undervoltage (Error 0x3294/0x135)
This fault applies to the PSM 510, DAM 510, and ACM 510.
Possible Causes
•
Incorrect U
supply.
AUX
•
Incorrect current dimensioning of the supply equipment.
Troubleshooting
•
Check that the supply matches the auxiliary supply requirements.
•
Check that the output power of the supply is sufficient.
Danfoss A/S © 2020.08
line than allowed.
AUX
Diagnostics
AQ262449648484en-000101 / 175R1135 | 159
Need help?
Do you have a question about the VLT ISD 510 and is the answer not in the manual?
Questions and answers