Danfoss VLT ISD 510 Operating Manual page 204

Servo drive system
Hide thumbs Also See for VLT ISD 510:
Table of Contents

Advertisement

VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
11.9.2 Brake Connectors
Brake connectors are located on the Power Supply Module (PSM 510).
11.9.2.1 Brake Resistor Connector on PSM 510
Illustration 142: Brake Connector on PSM 510
Table 135: Pin Assignment of Brake Connector on PSM 510
Pins (left to
Description
right)
1
DC+/R+
2
R–
-
The maximum length of the brake cable is 30 m (shielded).
11.9.3 Ethernet Connectors
Ethernet connectors are located on all the system modules.
1
8
Illustration 143: Ethernet Connector
-
Only PELV potential can be connected to the digital inputs and outputs.
11.9.3.1 Ethernet Connectors on PSM 510 and ACM 510
Table 136: Ethernet Connectors on PSM 510 and ACM 510
Connector name
X1 IN
X2 OUT
204 | Danfoss A/S © 2020.08
Notes
Used for connecting a brake re-
sistor.
N O T I C E
N O T I C E
Description
Ethernet IN
Ethernet OUT1
Ratings
Nominal voltage: 560–800 V DC
Maximum brake current: 80 A
Conductor cross-section range: 0.75–16 mm
Pins
Ratings
According to standard 100BASE-T.
1: TX+
2: TX–
3: RX+
4: –
5: –
6: RX–
7: –
8: –
Specifications
2
(AWG 18–AWG 4)
AQ262449648484en-000101 / 175R1135

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT ISD 510 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Vlt dsd 510

Table of Contents