VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
9.2.1.10 Drive Speed Drops Sharply under Load
Possible Cause
•
Drive is running at current limit.
•
Drive is running with incorrect parameters.
Troubleshooting
•
Check the application.
•
Check the parameter settings.
9.2.1.11 Brake not Releasing
Possible Cause
•
Defective brake control.
•
Incorrect mechanical brake parameters.
Troubleshooting
•
Check the parameter settings.
•
Contact Danfoss.
9.2.1.12 Holding Brake not Holding the Servo Drive
Possible Cause
•
Mechanical brake defective.
•
Shaft load exceeds the holding torque of the brake.
Troubleshooting
•
Contact Danfoss.
9.2.1.13 Delayed Brake Engagement
Possible Cause
•
Software error.
Troubleshooting
•
Contact Danfoss.
9.2.1.14 Noises when Power-Off Brake is Engaged
Possible Cause
•
Mechanical brake damaged.
Troubleshooting
•
Contact Danfoss.
9.2.1.15 LEDs not Lighting Up
Possible Cause
•
No power supply.
Troubleshooting
•
Check the power supply.
9.2.1.16 Drive Protection Trips Immediately
Possible Cause
•
Short circuit.
•
Incorrect control loop parameters.
Troubleshooting
•
Check the wiring.
•
Contact Danfoss.