VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
Table 62: UAUX high voltage (0x3291 / 0x132)
Code
PROFINET
code
®
0x3291
0x132
9.3.23 UAUX overvoltage (0x3292 / 0x133)
This error is valid for DAM 510.
Table 63: UAUX overvoltage (0x3292 / 0x133)
Code
PROFINET
code
®
0x3292
0x133
9.3.24 UAUX low voltage (0x3293 / 0x134)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 64: UAUX low voltage (0x3293 / 0x134)
Code
PROFINET
code
®
0x3293
0x134
9.3.25 UAUX undervoltage (0x3294 / 0x135)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 65: UAUX undervoltage (0x3294 / 0x135)
Code
PROFINET
code
®
0x3294
0x135
9.3.26 DC link high voltage (0x3295 / 0x136)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 66: DC link high voltage (0x3295 / 0x136)
Code
PROFINET
®
code
0x3295
0x136
9.3.27 DC link low voltage (0x3296 / 0x137)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 67: UDC low voltage (0x3296 / 0x137)
Code
PROFINET
®
code
0x3296
0x137
Danfoss A/S © 2020.08
Name
Severity (warning/error/trip
lock)
U
high voltage
Warning
AUX
Name
Severity (warning/error/trip
lock)
U
overvolt-
Error
AUX
age
Name
Severity (warning/error/trip lock)
U
low voltage
Warning
AUX
Name
Severity (warning/error/
trip lock)
U
undervolt-
Error
AUX
age
Name
Severity (warning/
error/trip lock)
DC link high
Warning
voltage
Name
Severity (warning/
error/trip lock)
DC link low
Warning
voltage
Description
U
above warning limit.
AUX
Description
U
above overvoltage limit.
AUX
Description
U
below warning limit.
AUX
Description
U
below undervoltage
AUX
limit.
Description
The DC-link voltage is higher than the
high-voltage warning limit.
Description
The DC-link voltage is lower than the
low-voltage warning limit.
AQ262449648484en-000101 / 175R1135 | 165
Diagnostics
LCP name
UAUX high volt
LCP name
UAUX overvolt
LCP name
UAUX low volt
LCP name
UAUX undervolt
LCP name
UDC high volt
LCP name
UDC low volt