VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
Mechanical Installation
Rmin
37
[1.45]
Illustration 19: Minimum Distance for M23 Straight Connector
4.7.1.2 Minimum Distance for M23 Angled Connector on ISD 510
The minimum distance for the angled connector is calculated as follows:
0.5 x cable diameter + connector length measured from electronic housing + R
= 7.8 mm + 51.4 mm + 78 mm = 137.8 mm ≈
min
140 mm
140 min
[5.51]
51.4
[2.02]
Rmin
Illustration 20: Minimum Distance for M23 Angled Connector
4.7.2 Space Requirements for DSD 510 Servo Drive
In addition to its own dimensions, the DSD 510 servo drive needs space for the hybrid cable.
4.7.2.1 Minimum Distance for M23 Straight Connector on DSD 510
shows the straight connector installed on a DSD 510 servo drive.
4.7.2.2 Minimum Distance for M23 Angled Connector on DSD 510
shows the angled connector installed on a DSD 510 servo drive.
The illustrations show the minimum distance from the servo drive to the next object, and the minimum allowable bending radius
R
for permanently installed cable. For cable installation, allow the height of the connector plus an additional 30 mm for the cable.
min
Danfoss A/S © 2020.08
AQ262449648484en-000101 / 175R1135 | 51
Need help?
Do you have a question about the VLT ISD 510 and is the answer not in the manual?
Questions and answers