VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
-
Constants which are needed internally for the library.
-
They are not intended to be used in an application.
DDS_LabCam
-
Constants for the creation of labeling CAMs.
DDS_SdoAbortCodes
-
Constants for errors concerning reading and writing of parameters.
-
The reason is given in an output AbortCode that is available in several POUs.
PSM_ErrorCodes
-
Constants for error codes of the Power Supply Module (PSM 510).
-
Error codes can be read using the function block DD_ReadPsmError_PSM and/or DD_ReadPsmWarning_PSM.
PSM_TraceSignals
-
Constants for the trace signals of the Power Supply Module (PSM 510).
-
Intended to be used with the function block DD_Trace_PSM.
DAM_ErrorCodes
-
Constants for error codes of the Decentral Access Module (DAM 510).
-
Error codes can be read using the function block DD_ReadDamError_DAM and/or DD_ReadDamWarning_DAM.
DAM_TraceSignals
-
Constants for the trace signals of the Decentral Access Module (DAM 510).
-
Intended to be used with the function block DD_Trace_DAM.
ACM_ErrorCodes
-
Constants for error codes of the Auxiliary Capacitors Module (ACM 510).
-
Error codes can be read using the function block DD_ReadAcmError_ACM and/or DD_ReadAcmWarning_ACM.
ACM_TraceSignals
-
Constants for the trace signals of the Auxiliary Capacitors Module (ACM 510).
-
Intended to be used with the function block DD_Trace_ACM.
6.11.5 Instantiating AXIS_REF_DDS in TwinCAT®
Procedure
1.
Create 1 instance of function block AXIS_REF_DDS (located in folder DDS_Drive) for the ISD 510 servo drive that has to be
controlled or monitored.
2.
Repeat step 1 for each additional servo drive.
98 | Danfoss A/S © 2020.08
Commissioning
AQ262449648484en-000101 / 175R1135