VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
Specifications
Weight
Dimensions
(W x H x D)
Dimensions: 470 x 270 x 10 mm [18.5 x 10.6 x 0.4 inch]
1
11.2.4 Characteristic Data for Power Supply Module (PSM 510)
Table 124: Characteristic Data for PSM 510
Definition
Input
Mains input voltage
Input current @ U
MIN
Input power
U
input voltage
AUX
U
current consumption at 24 V DC
AUX
U
current consumption at 48 V DC
AUX
Output
DC-link voltage
DC-link capacitance
Rated current I
N
Rated power P
N
Peak power P
t <3.0 s)
max
Internal brake resistor
(1)
Peak power P
max
Rated power P
N
Nominal resistance
External brake resistor
Peak power P
max
Rated power P
N
Minimum resistance
General
Protective measures
Line filter in accordance with EN 61800-3
Cooling
Danfoss A/S © 2020.08
Unit
kg [lbs]
mm
Unit
Power size 1
V AC
400–480 ±10%, 3-phase (see
A
20
VA
12.5
V DC
A DC
A DC
V DC
µF
A
20
kW
10
kW
20
kW
W
kW
kW
Overload, short-circuit, and ground fault protection
DSD 510
2.85 [6.28]
107.8 x 330.5 x 84
Power size 2
Power size 3
5.2 Electrical Environmental
34
22
24/48 ±10%
2.0
1.0
565–680 ±10%
1800
40
20
40
8
150
15
60
7.5
10
Category C3
Integrated fan
AQ262449648484en-000101 / 175R1135 | 189
Specifications
Conditions)
50
32
60
30
60