Danfoss VLT ISD 510 Operating Manual page 187

Servo drive system
Hide thumbs Also See for VLT ISD 510:
Table of Contents

Advertisement

VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
Specifica-
Unit
Size 1,
tions
1.5 Nm
Rated power
kW
0.72 [0.98]
P
[hp]
N
Standstill
Nm
2.3
(stall) torque
M
0
Standstill
A DC
2.1
(stall) cur-
rent I
0
Peak torque
Nm
6.1
M
max
Peak current
A DC
5.7
(rms value)
I
max
Rated volt-
V DC
age
Inductance
mH
18.5
L ph-ph
Resistance
9.01
R ph-ph
Voltage con-
V/
70.6
stant EMK
krpm
Torque con-
Nm/A
1.10
stant K
t
2
Inertia
Kgm
0.000085
Protective
Overload, short-circuit, and ground fault protection.
measures
Maximum
Hz
590
output fre-
quency
Shaft diame-
mm
14 [0.55]
ter
[inch]
Pole pairs
4
Flange size
mm
76 [2.99]
[inch]
Functional
safety
Cooling
Mounting
Weight
kg
3.5 [7.7]
[lbs]
In preparation
1
Danfoss A/S © 2020.08
Size 2,
Size 2,
Size 2,
2.1 Nm
2.9 Nm
3.8 Nm
0.88 [1.20]
0.94
[1.28]
2.8
3.6
4.6
2.3
2.1
2.2
7.8
10.7
12.7
6.4
26.8
32.6
33.9
7.78
8.61
8.64
80.9
111.0
132.0
1.26
1.72
2.04
0.00015
0.00021
0.00027
19 [0.75]
84 [3.31]
4.0 [8.8]
5.0 [11.0]
6.0 [13.2]
Size 3,
Size 3,
5.2 Nm
6.0 Nm
1.6 [2.18]
1.9 [2.58]
6.6
8.6
4.6
4.9
21.6
29.9
17.7
19.8
565–680 ±10%
11.9
11.4
2.35
2.10
92.7
112.0
1.22
1.51
0.00062
0.00091
24 [0.94]
5
108 [4.25]
STO
Via flange
Via flange
8.3 [18.3]
10.0
[22.0]
AQ262449648484en-000101 / 175R1135 | 187
Specifications
Size 4,
Size 4,
11.2 Nm
13.0 Nm
(1)
2.3 [3.13]
13.3
5.6
38.6
21.2
18.0
2.26
158.8
1.82
0.0024
32 [1.26]
138 [5.43]
13.8 [30.4]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt dsd 510

Table of Contents